Blueair
Blue Pure 211+ Auto
AHAM Verifide at 353 cfm smoke CADR for a 550 sq ft room, and Blueair publishes exactly those numbers rather than a flattering pair — which almost nothing else in this catalogue does. It draws 4 W on its lowest speed.
A 22-inch tower with a UV-C lamp, rated by GermGuardian at 99 cfm smoke CADR. Its honest coverage figure is 153 sq ft — the 743 sq ft in the listings is the same machine at roughly one air change per hour.
Pros
Cons
Verdict
The AC4825 is the small, light, three-consumable option. Its honest coverage is 153 sq ft, and GermGuardian deserves credit for publishing that figure — as 12.5 minutes per room volume, which is 4.8 air changes an hour — right next to the 743 sq ft that fills the listings. At 8.55 lb it is the only machine here you would genuinely carry between rooms. The two things to weigh are the running cost and the lamp. Filter B, a carbon pre-filter every two to three months and a UV-C bulb are three separate purchases, which makes any comparison against a one-filter-a-year machine misleading unless you do the arithmetic. And CARB has classified every AC4825 variant as Electronic since 2012 because of that lamp: certified and ozone-tested, but not the same kind of machine as a Mechanical one, and we could not find out whether the lamp can be turned off.
Check which revision you receive
Corrected on 14 September 2026. This page previously stated that no GermGuardian model appeared in the AHAM Verifide directory. That was drawn from AHAM's printed 2023 edition, which does not list the brand; the live directory lists fifteen GermGuardian models, including an AC4825E one letter away from this one. The AC4825 itself is still not among them, so this model's CADR remains the manufacturer's own — but the surrounding claim about the brand was wrong and has been replaced with what the certified siblings actually measure.
Price, seller and package contents change. Check the variant on Amazon before you buy.
Who it's for
Who should skip it
How this coverage figure is stated
4.8 air changes per hour — and GermGuardian does publish it, just not in those words. Its wording is "Cleans a 153 sq. ft. room in just 12.5 minutes or up to 743 sq. ft. every hour".
Twelve and a half minutes per room-volume is sixty divided by 12.5, which is 4.8 changes an hour. So the 153 ft² IS the comparable figure, expressed as a time instead of a rate. It also reconciles with the arithmetic: 99 x 1.55 = 153.
The 743 ft² is the same machine at ONE change an hour — and GermGuardian says so itself: its listing reads "circulating air in a 153 sq. ft. room every 12.5 minutes, or once per hour in medium to large rooms up to 743 sq. ft." Both numbers are true; only one of them is comparable with the rest of this site, and it is the smaller one.
Always compare two purifiers at the same air-change rate; manufacturers pick different ones and the headline square footage is not otherwise comparable.
| Smoke CADR (manufacturer-stated) | 99 cfm GermGuardian's own figure; AHAM not claimed |
|---|---|
| Coverage | "Cleans a 153 sq. ft. room in just 12.5 minutes or up to 743 sq. ft. every hour" 12.5 minutes is 4.8 air changes an hour |
| CARB | Certified, device type Electronic, notified 2012-01-17, executive order G-12-006 |
| Noise | 40 dBA on low, 55 dBA on high |
| Dust CADR (manufacturer-stated) | 118 cfm |
| Pollen CADR (manufacturer-stated) | 125 |
| Dimensions | 22.00 x 10.25 x 6.75 in |
|---|---|
| Weight | 8.55 lb |
| AHAM Verifide | No GermGuardian model appears in the October 2023 AHAM directory |
| Consumables | THREE: Filter B (FLT4825) carbon pre-filter (FLT22CB4, every 2-3 months), UV bulb (LB4000) |
| Energy Star | Not certified |
Our calculation, not the manufacturer’s
| Air changes | When you want this rate | Room it suits |
|---|---|---|
| 4.8×/hour | Wildfire smoke, allergy season, a room you are sensitive in | 155 ft² |
| 4×/hour | The rate most allergy guidance assumes | 186 ft² |
| 2×/hour | General freshening in a room without a specific problem | 371 ft² |
Worked from the CDC/NIOSH relation
air changes = (CADR × 60) ÷ (area × ceiling height),
assuming an 8 ft ceiling. Change the ceiling height and these
numbers change. AHAM’s own consumer rule — a smoke CADR of at
least two-thirds of the room’s area — puts the ceiling for this
unit at about 149 ft², which is the same arithmetic
at roughly five air changes an hour.
This CADR is the manufacturer’s own figure, not an AHAM Verifide
measurement, so treat it as a claim rather than a verified result.
You can check this at home. In a closed room of the size in the first row, PM2.5 should halve about every nine minutes at top speed once its source stops. A monitor shows whether this unit manages that in your home. How to run the test
Ionizer and ozone
⚠️ THIS MACHINE HAS A UV-C LAMP, AND CALIFORNIA CLASSIFIES IT ACCORDINGLY. CARB's complete certified list carries a long run of AC4825 variants — AC4825, AC4825CA, AC4825T, AC4825PT, AC4825TPT, AC4825TBPT, AC4825TWPT and others — all as "3 in 1 Air Cleaning System", all ELECTRONIC, all under executive order G-12-006, notified 2012-01-17.
Electronic means California's certifier identified a component capable of producing ozone and therefore tested the unit against the state's emission limit, which it passed. It is certified, not banned. But it is a different kind of machine from a CARB-Mechanical one, and on this site the Levoit Core 400S and the Coway Airmega 400 sit on the other side of that line.
CAN THE LAMP BE TURNED OFF? THE ONLY WORDING WE FOUND IS AMBIGUOUS. GermGuardian's own Amazon listing describes the machine as having an "optional UV-C light". That reads as switchable — but "optional" can equally mean optionally fitted on some variants, and its product page says nothing either way. We are not going to resolve a word like that in the manufacturer's favour. If running without the lamp matters to you, ask before buying.
| Capability | What it needs | Status |
|---|---|---|
| Particle filtration | Filter B, pre-installed | Included |
| Odour reduction | Carbon pre-filter FLT22CB4 — replaced every 2-3 months | Sold separately |
| UV-C stage | LB4000 lamp; replacement bulb sold separately | Sold separately |
| Replacement particle filter | FLT4825 or one of its media variants, sold separately | Sold separately |
| Air quality sensor or auto mode | Not documented for this model | Not verified |
| Ability to switch the UV lamp off | Not stated by the manufacturer | Not verified |
Package contents vary by variant and seller. Check what is in the box on the Amazon listing before you buy. “Not verified” means the manufacturer does not document it either way — not that it is missing. “Not offered” is the other thing: the manufacturer does document it, and the answer is that this model does not have it.
GermGuardian Filter B (FLT4825)
Part FLT4825 / FLT4825SM / FLT4825VO / FLT4850PT / FLT22CB4 / LB4000 · ⚠️ GERMGUARDIAN DOES NOT STATE AN INTERVAL FOR FILTER B ON THE PRODUCT PAGE ITSELF. Checked 14-sep-2026: the page lists what the filter fits and states it is not washable, and gives no replacement period. What the manufacturer does document on the same product page is the interval for the OTHER consumable: the activated carbon pre-filter FLT22CB4 is "replaceable every 2-3 months". So on this unit the figure you can rely on is for the part that is not the main filter. Treat visible loading and airflow as the signal for Filter B rather than a date, and budget for the pre-filter four to six times a year regardless.
Checked against the AHAM Verifide directory, CARB's certified air-cleaner list and the manufacturer's own pages. We did not test this unit. Nothing here is a measurement of ours: every figure is either documented by the manufacturer or published by an independent standards or testing body, and where the two disagree this page says so.
Blueair
AHAM Verifide at 353 cfm smoke CADR for a 550 sq ft room, and Blueair publishes exactly those numbers rather than a flattering pair — which almost nothing else in this catalogue does. It draws 4 W on its lowest speed.
Blueair
AHAM Verifide at 283 cfm smoke for a 439 sq ft room, and the rare case where the electrostatic question has an actual number attached: ENERGY STAR measured its ozone emission at 2 ppb.
Blueair
A compact tower with an AHAM Verifide smoke CADR of 123 cfm and a 190 sq ft AHAM room size. CARB classifies it Electronic, which is a consequence of how Blueair's HEPASilent works rather than a fault.